Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Talanta ; 275: 126125, 2024 Apr 24.
Article in English | MEDLINE | ID: mdl-38663066

ABSTRACT

The establishment of rapid target analysis methods for cytokeratin fragment antigen 21-1 (CYFRA 21-1) is urgently needed. [Ir(pbi)2(acac)] (pbi = 2-(4-bromophenyl)-1-hydrogen -benzimidazole, acac = acetylacetonate) as traditional electrochemiluminescence (ECL) luminophores has been confined due to its non-negligible dark toxicity and poor water solubility leading to poor biocompatibility and electrical conductivity as an organic molecule. Hence, to overcome this limitation, [Ir(pbi)2(acac)] can be effectively loaded on the polyvinyl alcohol hydrogel modified Ti3C2Tx MXene surface (Ir@Ti3C2Tx-PVA) as sensing platform which can emit high ECL signals. Then, a quenching strategy was proposed to fabricate an ECL sandwich immunosensor using H2O2 as quencher molecules which can generated by Pd@Au0.85Pd0.15. Especially, the generation of O2 to H2O2 can be achieved through a two-electron (2e-) reaction pathway by Pd@Au0.85Pd0.15, to overcome the restriction that the H2O2 was virtually impossible to label or immobilize on the non-enzyme nanomaterials. The proposed ECL assay achieves a response to CYFRA 21-1 within the range of 0.1 pg/mL-100 ng/mL, with a detection limit of 8.9 fg/mL (S/N = 3). This work provided a feasible tactic to seek superior-performance ECL luminophore and quencher consequently set up a novel means to makeup ultrasensitive ECL biosensor, which extended the utilization potential of Ir(pbi)2(acac) in ECL assays.

2.
ACS Sens ; 9(4): 1992-1999, 2024 Apr 26.
Article in English | MEDLINE | ID: mdl-38536770

ABSTRACT

The construction of assays is capable of accurately detecting cytokeratin-19 (CYFRA 21-1), which is critical for the rapid diagnosis of nonsmall cell lung cancer. In this work, a novel electrochemiluminescence (ECL) immunosensor based on the co-reaction promotion of luminol@Au@Ni-Co nanocages (NCs) as ECL probe by Ti3C2Tx MXene@TiO2-MoS2 hybrids as co-reaction accelerator was proposed to detect CYFRA 21-1. Ni-Co NCs, as a derivative of Prussian blue analogs, can be loaded with large quantities of Au NPs, luminol, and CYFRA 21-1 secondary antibodies due to their high specific surface area. To further improve the sensitivity of the developed ECL immunosensor, Ti3C2Tx MXene@TiO2-MoS2 hybrids were prepared by in situ growth of TiO2 nanosheets on highly conductive Ti3C2Tx MXene, and MoS2 was homogeneously grown on Ti3C2Tx MXene@TiO2 surfaces by the hydrothermal method. Ti3C2Tx MXene@TiO2-MoS2 hybrids possess excellent catalytic performance on the electro-redox of H2O2 generating more O2·- and obtaining optimal ECL intensity of the luminol/H2O2 system. Under the appropriate experimental conditions, the quantitative detection range of CYFRA 21-1 was from 0.1 pg mL-1 to 100 ng mL-1, and the limit of detection (LOD) was 0.046 pg mL-1. The present sensor has a lower LOD with a wider linear range, which provides a new analytical assay for the early diagnosis of small-cell-type lung cancer labels.


Subject(s)
Antigens, Neoplasm , Biosensing Techniques , Disulfides , Electrochemical Techniques , Gold , Keratin-19 , Luminescent Measurements , Luminol , Molybdenum , Titanium , Keratin-19/blood , Keratin-19/immunology , Titanium/chemistry , Luminol/chemistry , Molybdenum/chemistry , Gold/chemistry , Antigens, Neoplasm/immunology , Electrochemical Techniques/methods , Humans , Biosensing Techniques/methods , Luminescent Measurements/methods , Immunoassay/methods , Disulfides/chemistry , Limit of Detection , Nickel/chemistry , Cobalt/chemistry , Metal Nanoparticles/chemistry , Antibodies, Immobilized/immunology , Antibodies, Immobilized/chemistry
3.
Talanta ; 273: 125959, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38537493

ABSTRACT

The improvement of electrochemiluminescence (ECL) performance relies on the electron transfer efficiency between luminophore and coreactant. An ultrasensitive ECL micro-reactor with confinement-enhanced performance was prepared by using the covalent organic framework-LZU1-functionalized metal-organic framework (MOF@COF-LZU1) as a platform to assemble enormous N,N-dibutyl-2-hydroxyethylamine (DBAE) and tris(4,4'-dicarboxylic acid-2,2'-bipyridyl) ruthenium(II) [Ru(dcbpy)32+] into its pore channels. Compared to individual substances of γ-CD-MOF and COF-LZU1, the synergistic effects can conduce to the enhancement of the intensity, durability and sensitivity of the micro-reactor. Besides, COF-LZU1 can provide a mild environment to accommodate a certain amount of DBAE by concentrating them from the aqueous solution into its hydrophobic cavities and boost the oxidation efficiency of DBAE to generate more DBAE●+ and profited the survival of DBAE●, leading to an improved reaction efficiency with the Ru(dcbpy)32+ intermediate. Thanks to the confinement-enhanced strategy, engineered as high-functioning luminescent materials, Ru@γ-CD-MOF@COF-LZU1 micro-reactors decorated with Au NPs can facilitate electron transfer and capture primary antibodies (Ab1). Moreover, Au-Pd-Pt noble metal aerogels (NMAs) functionalized MoS2 NFs (Au-Pd-Pt NMAs@MoS2 NFs) were chosen as base material due to its large specific surface areas, high porosity, and excellent electrical conductivity. Based on above merits, the sensor demonstrated a sensitive response to CYFRA 21-1 detection in a linear concentration gradient from 10 fg/mL to 50 ng/mL with a detection limit of 0.0055 pg/mL (S/N = 3). The COF-LZU1 decorated ECL micro-reactors were constructed based on the signal amplification strategies to realize accurate CYFRA 21-1 detection.

4.
Anal Chim Acta ; 1287: 342091, 2024 Jan 25.
Article in English | MEDLINE | ID: mdl-38182343

ABSTRACT

BACKGROUND: Carcinoembryonic antigen (CEA) is a significant glycosylated protein, and the unusual expression of CEA in human serum is used as a tumor marker in the clinical diagnosis of many cancers. Although scientists have reported many ways to detect CEA in recent years, such as electrochemistry, photoelectrochemistry, and fluorescence, their operation is complex and sensitivity is average. Therefore, finding a convenient method to accurately detect CEA is significance for the prevention of malignant tumors. With high sensitivity, quick reaction, and low background, electrochemiluminescence (ECL) has emerged as an essential method for the detection of tumor markers in blood. RESULTS: In this work, a "signal on-off" ECL immunosensor for sensitive analysis of CEA ground on the ternary extinction effects of CuFe2O4@PDA-MB towards a self-enhanced Ru(dcbpy)32+ functionalized metal-organic layer [(Hf)MOL-Ru-PEI-Pd] was prepared. The high ECL efficiency of (Hf)MOL-Ru-PEI-Pd originated from the dual intramolecular self-catalysis, including intramolecular co-reaction between polyethylenimine (PEI) and Ru(dcbpy)32+. At the same time, loading Pd NPs onto (Hf)MOL-Ru-PEI could not only improve the electron transfer ability of (Hf)MOL-Ru-PEI, but also provide more active sites for the reaction of Ru(dcbpy)32+ and PEI. In the presence of CEA, CuFe2O4@PDA-MB-Ab2 efficiently quenches the excited states of (Hf)MOL-Ru-PEI-Pd by PDA, Cu2+, and methylene blue (MB) via energy and electron transfer, leading to an ECL signal decrease. Under optimal conditions, the proposed CEA sensing strategy showed satisfactory properties ranging from 0.1 pg mL-1 to 100 ng mL-1 with a detection limit of 20 fg mL-1. SIGNIFICANCE: The (Hf)MOL-Ru-PEI-Pd and CuFe2O4@PDA-MB were prepared in this work might open up innovative directions to synthesize luminescence-functionalized MOLs and effective quencher. Besides, the ECL quenching mechanism of Ru(dcbpy)32+ by MB was successfully explained by the inner filter effect (ECL-IFE). At last, the proposed immunosensor exhibits excellent repeatability, stability, and selectivity, and may provide an attractive way for CEA and other disease markers determination.


Subject(s)
Biosensing Techniques , Carcinoembryonic Antigen , Humans , Biomarkers, Tumor , Carcinoembryonic Antigen/chemistry , Carcinoembryonic Antigen/immunology , Immunoassay , Metals , Methylene Blue , Ferric Compounds/chemistry , Copper/chemistry , Ruthenium/chemistry
SELECTION OF CITATIONS
SEARCH DETAIL
...